Who Can Inspect Eyebolts on Your Building?
A roof eyebolt may look like a simple steel fixing. It is not. It is a designated fall-protection anchor, often relied upon by contractors working at height with no second chance if it fails. So, who can inspect eyebolts? A competent person with the specific training, practical experience and technical knowledge to inspect anchor devices against the manufacturer’s requirements, relevant British Standards and the installation’s intended use.
For facilities and estates teams, the issue is not simply arranging an annual visit. The real test is whether the inspector can identify a defective anchor, understand the load path behind it, make a defensible pass or fail decision, and issue the documentation your auditor actually wants to see.
Who can inspect eyebolts under UK requirements?
There is no single government-issued licence that automatically qualifies someone to inspect every roof eyebolt. Competence is determined by the individual’s combination of training, knowledge, experience and authority to make inspection decisions.
For fall-arrest eyebolts, the inspector should be trained and experienced in personal fall-protection systems and anchor devices. They must understand the product type, its fixing method, the substrate it is installed into and the hazards created by deterioration, alteration or misuse. An engineer who is generally competent on roofs is not automatically competent to certify an eyebolt.
A suitable inspector will normally have manufacturer-specific or recognised anchor-device inspection training, practical experience of testing and examining fall-protection systems, and current knowledge of standards including BS EN 795 and BS 7883. They should also be able to assess the wider system. An eyebolt can appear sound at roof level while concealed fixings, structural supports or waterproofing details have compromised its capacity.
The person or company must be independent enough to make a clear decision. If an anchor fails, it should be marked out of service and reported as such. There is no value in a certificate that avoids difficult findings to keep a site operational for another day.
Competence means more than a visual check
A visual condition check is part of an inspection, but it is not the whole job. The inspector needs to verify that the eyebolt remains suitable for its specified use, whether that is fall arrest, rope access, work restraint or another controlled activity.
That means examining the anchor body for corrosion, deformation, cracking, wear, unauthorised modification and damaged threads. It also means checking the identification marking, installation date where available, user capacity and any manufacturer restrictions. Missing identification is not a minor paperwork issue. If the equipment cannot be traced to its specification or installation record, its safe use may not be demonstrable.
The fixing and supporting structure matter just as much. A resin-fixed eyebolt in concrete requires a different inspection approach from a through-fixed unit on a steel structure or an anchor installed through a built-up roof system. The inspector must understand what sits below the roof finish and whether water ingress, substrate deterioration or previous repair work has affected the installation.
Load testing may be required where specified by the manufacturer, the installation design, the asset history or the inspection findings. It is not a substitute for competent examination, and it should not be carried out as a routine exercise without considering the anchor type and supporting structure. Incorrect testing can create damage rather than prove safety.
Standards and legal duties that shape eyebolt inspection
For permanent fall-protection anchors, BS EN 795 is the central product standard. Individual eyebolts are commonly classified as Type A anchor devices, designed to be fixed to a vertical, horizontal or inclined surface. BS 7883 provides the UK code of practice for the design, selection, installation, use and maintenance of anchor devices conforming to BS EN 795.
The Work at Height Regulations 2005 require duty holders to plan, supervise and carry out work at height by competent people. Where eyebolts are provided as part of the control measure, leaving their condition unknown creates an obvious gap in that planning. An expired certificate does not necessarily prove physical failure, but it does mean the asset is non-compliant by default until its status is confirmed.
Inspection intervals should follow the manufacturer’s instructions, site risk assessment and system design. In many cases, annual inspection is expected. Higher-use environments, exposed coastal locations, corrosive industrial sites, sites with known misuse or anchors used for rope access may require more frequent examination. The correct interval is the one supported by the equipment requirements and the actual risk, not the one that happens to fit the maintenance calendar.
There is a separate point for lifting eyebolts. Eyebolts used as lifting accessories fall under a different regime and may require thorough examination under LOLER. A roof safety eyebolt used for personal fall protection is not automatically a LOLER item. Confusing the two can lead to the wrong inspection process, the wrong certificate and false assurance.
When an existing certificate is not enough
A certificate only has value if it identifies exactly what has been inspected and what decision was made. Generic sheets stating that multiple anchors are ‘satisfactory’ are weak evidence, particularly on large or complex estates.
A reliable inspection record should identify each eyebolt by a unique reference, location and photograph. It should record the anchor type, its intended use, inspection date, due date, condition, any tests completed and an unambiguous pass, fail or advisory outcome. Defects should be supported by photographs and a clear recommendation for remedial action.
If the installation records are missing, the inspector may need to investigate further before recertification. This can include reviewing original drawings, checking fixing details, opening up local areas where appropriate or obtaining structural confirmation. It may be inconvenient, but certifying an unknown anchor simply because it looks serviceable is not a defensible approach.
What a competent eyebolt inspection should deliver
Facilities managers need more than a site visit. They need a controlled process that leaves no doubt about the condition of the asset register and the actions required.
A proper inspection begins with a review of the existing register, previous certificates, defect history and access arrangements. On site, the inspector should confirm every asset against the register, assess its condition and record any additions, missing items or inaccessible locations. If an eyebolt cannot be inspected, it cannot be assumed compliant.
The report should separate immediate safety failures from planned maintenance items. An anchor with serious corrosion, movement, damaged fixing points or missing traceability may require immediate removal from service. That decision needs a visible tag or other control on site, not just a note buried in a report issued later.
For failed assets, the next step should be proportionate. Some defects can be resolved through replacement or local remediation. Others require a design review because the underlying roof construction, substrate or access arrangement is unsuitable. The same team should be able to inspect, explain the defect, complete the remedial work and provide the final certification. No subcontracted gaps in the chain and no missing paperwork.
Questions to ask an eyebolt inspection provider
Before appointing a contractor, ask who will carry out the work and what specific fall-protection inspection training and experience they hold. Ask whether they inspect the anchor and its fixing system, not merely the visible eye.
Also ask what standard their reports follow, whether every anchor is individually identified and photographed, and how failed items are controlled before repairs are completed. A provider should be able to explain when testing is appropriate, what limitations apply and how they deal with missing installation records.
Finally, establish who owns the action after a fail result. A report without a clear remedial route leaves the duty holder managing the highest-risk part of the process alone. Sky Height Safety uses in-house engineers, asset-specific evidence and clear pass or fail reporting so estates teams can move from inspection to certified handover without ambiguity.
An eyebolt certificate is not a paper exercise. It is evidence that a person who may depend on that anchor has been given a system whose condition is known, whose defects are controlled and whose records will stand up to scrutiny. Arrange inspection before access is needed, keep the register current, and treat every failed or unverified anchor as unavailable until competent remedial action is complete.